DC 5V 80A 400W Switch Modus Power Supple
Video
Formularium:
EXEMPLUM | HSJ-400-5 | |
REFERO | DC VOLTAGE | 5V |
RATED current | 80A | |
Current range | 0 ~ 80A | |
RATED POTESTAS | 400W | |
CLAVIS & SONITUS (max.) Note.2 | 100mVp-p | |
VOLTAGE ADJ.TRACTUS | 4.5 ~ 5.5V | |
VOLTAGE TOLERATIO Note.3 | ±3.0% | |
ORDINATIO LINEA | ±0.5% | |
PONDUS DISSIGNATIO | ±2.0% | |
ERECTUS, ORTUS TEMPUS | 2500ms, 50ms/230VAC | |
TEMPUS SUSCIPIO (Typ.) | 20ms/230VAC | |
INPUT | VOLTAGE TRACTUS | 180 ~ 264VAC 254 ~ 370VDC |
FREQUENTIA TRACTUS | 47 ~ 63Hz | |
EFFICACITAS (Typ.) | 79% | |
AC HODIERNA (Typ.) | 5A/230VAC | |
INCURSUS current (Typ.) | 100A/230VAC | |
ultrices current | <1mA / 240VAC | |
PRAESIDIUM | SUPER PONDUS | 105 ~ 140% output rated potentia |
Praesidium genus: hiccup modus, automatice recuperat, postquam culpae conditio sublata est | ||
IN VOLTAGE | 115 ~ 150% | |
Praesidium genus: hiccup modus, automatice recuperat, postquam culpae conditio sublata est | ||
DE TEMPERATURA | Claudite O/P intentione, sponte recuperat postquam temperatus descendit | |
ENVIRONMENT | EXERCITATIO TEMP. | -20 ~ +60°C (Refer ad curvam) |
UMIDITAS EXERCITUS | 20~ 90% RH non-condensans | |
PRAECLUSIO TEMP., UMIDA | -20 ~ +85°C , 10 ~ 95% RH | |
TEMP.COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATIO | 10~ 500Hz, 3G 10min./1cyclus, 60min.singulae per axes X, Y, Z | |
SALUS | SALUS STANDARDS | U60950-1 probatus |
INTENTIO NOTA VI CONTINERE | I/PO/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
LOGINQUITAS RESISTENTES | I/PO/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/70% RH. | |
ALIIS' | MTBF | 235K hrs min.MIL-HDBK-217F (25°C ) |
DIMENSIONE | 215*115*30mm (L*W*H) | |
FASCICULUS | 0.85Kg;15pcs/14Kg/0.79CUFT | |
NOTA | 1. Omnes parametri NON nominatim mensurantur 230VAC initus, aestimatio oneris et 25°C temperaturae ambientis. |