Dual Output SMPS 12V25A 5V10A 400W Industrial dc power supply
Features:
Huyssen Daul Output Voltage Power Supple
AC input : 90-132V / 175-264V
Refrigerant in fan
Omnes utentes 105°C longam vitam electrolytici capacitors
Princeps operating temperatus usque ad LXX°C
Maximum efficientiam, longam vitam et altam fidem
DUXERIT indicator ad potentiam in
Plena onus caliditas ardent-in, 100% burn-in test
Praesidia: Brevis circuitus / per current / ONERO / Plus intentione
XXIV menses warantum
Formularium:
EXEMPLUM | HSJ-400-0512 | HSJ-400-3612 | HSJ-400-1248 | ||||
REFERO | REFERO NUMBER | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC VOLTAGE | 12V | 5V | 36V | 12V | 12V | 48V | |
RATED current | 25A | 10A | 10A | 3A | 9A | 6A | |
RATED POTESTAS | 400W | 400W | 400W | ||||
UNDA & SONITUS | 120mVp-p | 80mVp-p | 300mVp-p | 120mVp-p | 120mVp-p | 400mVp-p | |
VOLTAGETOLERANCE | ±2.0% | ±2.0% | ±2.0% | ±5.0% | ±4.0% | ±4.0% | |
LINEREGULATIO | ±0.5% | ±1.5% | ±0.5% | ±1.0% | ±0.5% | ±0.5% | |
LOADREGULATION | ±0.5% | ±3.0% | ±0.5% | ±2.0% | ±3.0% | ±3.0% | |
SETUP.RISEHOLD.TIME* | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC ad plenam sarcinam | ||||||
PRAETEMPTO | 80ms/230VAC 16ms/115VAC ad plenam sarcinam | ||||||
INPUT | VOLTAGE TRACTUS | 88~ 264VAC 125~ 373VDC (Sustine 300VAC fluctu pro 5sec. sine noxa) ; | |||||
FREQUENTIALITAS | 47~63HZ | ||||||
PRAESTANTIA | 81% | 85% | 87% | ||||
AC current | 0.9A/115VAC 0.6A/230VAC | ||||||
INCURSUS current | FRIGUS INITIUM 36A/230VAC | ||||||
LEAKAGECURRENT | <2mA/240VAC | ||||||
PRAESIDIUM | ONERO | CX ~ CL% rated output potentia | |||||
Praesidium genus: hiccup modus, statim post culpam recipit conditio remota | |||||||
IN VOLTAGE | ETIAM' | ETIAM' | |||||
Praesidium genus: hiccup modus, automatice recuperat, postquam culpae conditio sublata est | |||||||
ENVIRONMENT | EXERCITUS TIMP | -25~+70°C (Refer ad "Curvam Derate") | |||||
WORKINGHUMIDITY | 20~90% RH non-condensing | ||||||
PRAECLUSIO TEMP UMIDA | -40~+85°C 10~95%RH | ||||||
TEMPCOEFFICIENT | ±0.03%/ °C(0~50°C) in CH1 output | ||||||
VIBRATIO | 10~ 500Hz, 5G 10min./1cyclus, periodus 60min.singulae per axes X, Y, Z | ||||||
SALUS&EMC | SAFETYSTANDARDS | U60950, TUV EN60950 probatus | |||||
IMPEDIMENTUM VOLTAGE | I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
LOGINQUITAS | I/PO/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/70% RH. | ||||||
EMC EJECTUS | Obsequens EN55022 (CISPR22) Class B, EN61000-3-2,-3 . | ||||||
EMC IMMUNITATE | Obsequium ad EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), gravis industriae gradus, criteria A | ||||||
QTHERS | MTBF | 179Khrs min.MIL-HDBK-217F (25°C ) | |||||
DIMENSIONE | 215*115*50mm (L*W*H). | ||||||
FASCICULUS | 0.95Kg;20PCS/20Kg |
Applicationes:
Instrumentum industriae imperium, instrumenta sui muneris terminatio, apparatum medicinae, instrumentum communicationis, animationem productam, ludum solatur, apparatum venustatis, etc.