Dual Output 30V-30V 70W Equipment Switching Power Supple

Description:

Huyssen multae copiae copiae ex 40 Watts ad 600 Watts vagae sunt, intentionis intentionis ab 5 VDC ad 48VDC vel superiori.Dual output, triple output, et quad output praesto sunt, accipe mos.

Multae applicationes electronicarum & apparatuum multiplices intentiones requirunt ut varios circuitus internos suppeditent.Tempus, spatium, et argentum in aliquibus applicationibus conservare potest, commodo pro pluribus nos attinge.


Product Detail

Product Tags

Features:

·Huyssen Dual OutputPotestas Supple

Universale AC input: 90-264V

· Praesidia: brevis circuitus / ONERO / Plus voltage / super current

· refrigerationem libero aere convection

Maximum efficientiam, longam vitam et altam fidem

· Omnes usus 105°C longae vitae capacitores electrolytici

· Princeps operans temperamentum usque ad 70°C

· DUXERIT indicator potentiae on

· 100% plenum onus uri in test

·24 monthswarantiam

Formularium:

EXEMPLUM

HSJ-70-3030

HSJ-70-0512

HSJ-70-1212

REFERO

REFERO NUMBER

CH1

CH2

CH1

CH2

CH1

CH2

DC VOLTAGE

-30V

30V

5V

12V

-12V

12V

RATED current

0.3A

2A

4A

4A

2A

5.6A

RATED POTESTAS

70W

70W

70W

UNDA & SONITUS

300mVp-p

300mVp-p

80mVp-p

240mVp-p

300mVp-p

120mVp-p

VOLTAGETOLERANCE

±2.0%

±6.0%

±2.0%

±5.0%

±4.0%

±4.0%

LINEREGULATIO

±0.5%

±1.5%

±0.5%

±1.0%

±0.5%

±0.5%

LOADREGULATION

±0.5%

±3.0%

±0.5%

±2.0%

±3.0%

±3.0%

SETUP.RISEHOLD.TIME*

500ms, 30ms/230VAC 1200ms, 30ms/115VAC ad plenam sarcinam

PRAETEMPTO

80ms/230VAC 16ms/115VAC ad plenam sarcinam

INPUT

VOLTAGE TRACTUS

90~ 264VAC 125 ~ 373VDC (Tace 300VAC fluctu pro 5sec. sine noxa);

FREQUENTIALITAS

47~63HZ

PRAESTANTIA

84%

78%

82%

AC current

0.8A/115VAC 0.55A/230VAC

INCURSUS current

FRIGUS INITIUM 36A/230VAC

LEAKAGECURRENT

<2mA/240VAC

PRAESIDIUM

ONERO

CX ~ CL% rated output potentia

Praesidium genus: hiccup modus, statim post culpam recipit conditio remota

IN VOLTAGE

 ETIAM'

 ETIAM'

Praesidium genus: hiccup modus, automatice recuperat, postquam culpae conditio sublata est

ENVIRONMENT

EXERCITUS TIMP

-25~+70°C (Refer to "DeratingCurva")

WORKINGHUMIDITY

20~90% RH non-condensing

PRAECLUSIO TEMP UMIDA

-40~+85°C 10~95%RH

TEMPCOEFFICIENT

±0.03%/ °C(0~50°C) in CH1 output

VIBRATIO

10~ 500Hz, 5G 10min./1cyclus, periodus 60min.singulae per axes X, Y, Z

SALUS&EMC

SAFETYSTANDARDS

U60950, TUV EN60950 probatus

IMPEDIMENTUM VOLTAGE

I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

LOGINQUITAS

I/PO/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/70% RH.

EMC EJECTUS

Obsequens EN55022 (CISPR22) Classis B, EN61000-3-2,-3 .

EMC IMMUNITATE

Obsequium ad EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), gravis industriae gradus, criteria A

QTHERS

MTBF

179Khrs min.MIL-HDBK-217F (25°C )

DIMENSIONE

88*70*38mm (L*W*H)

FASCICULUS

0.4Kg;30PCS/9Kg

Applicationes:

Instrumentum industriae imperium, instrumenta sui muneris terminatio, apparatum medicinae, instrumenta communicationis, animationem productam, ludum solatur, apparatum venustatis, etc.

Applications pro potentia copia

Applications1
Applications2
Applications3
Applications4
Applications5
Applications6
Applications7
Applications8

Stipare & Delivery

by-plane1
navi
per, dolor
potestas copia stipare 500
paratus ad navem

Testimonia

Certificationes1
Certificaciones8
Certifications7
Certificaciones2
Certificaciones3
Certificaciones5
Certificaciones6
Certifications4

  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis